# Beckhoff CUxxxx Multiplier - emllMultiplier The parameters to the Multiplier Real-time Ethernet Driver are setup-specific. The function “CreateLinkParmsFromCmdLineMultiplier” in [`EcSelectLinkLayer.cpp`](_downloads/bf62c71a4a7e317930818b9da4a9815c/EcSelectLinkLayer.cpp) demonstrates how to initialize the Real-time Ethernet Driver instance. ### struct EC_T_LINK_PARMS_MULTIPLIER ### Public Members ### [EC_T_LINK_PARMS](emll_init.html.md#_CPPv415EC_T_LINK_PARMS) linkParms Common link parameters. Signature must be set to EC_LINK_PARMS_SIGNATURE_MULTIPLIER. ### [EC_T_MULTIPLIER_TYPE](#_CPPv420EC_T_MULTIPLIER_TYPE) eMultiplierType Type of the Multiplier Ethernet port ### [EC_T_DWORD](toc_api.html.md#_CPPv410EC_T_DWORD) dwPort Used CU2508 downlink port ### [EC_T_LINK_PARMS](emll_init.html.md#_CPPv415EC_T_LINK_PARMS) \*pHwLinkParms Link parameters of network adapter connected to the uplink of the Multiplier ### enum EC_T_MULTIPLIER_TYPE *Values:* ### enumerator eMultiplier_Cu2508 Beckhoff CU2508 port multiplier ### enumerator eMultiplier_Et2000 Beckhoff ET2000 industrial Ethernet multi-channel probe ## Configuration with EC-Engineer This configuration is valid for one downlink port. For each used CUxxxx multiplier downlink port, a new configuration should be arranged. - Start EC-Engineer in Offline Configuration modus. - Add the CU2508 Ethernet Port as your first SubDevice. ![EC-Engineer Offline Configuration showing the CU2508 Ethernet Port SubDevice added as the first device in the network topology](../Media/CU2508_Ethernet_Port.png) - Append the SubDevices that you are going to connect to the port. ![EC-Engineer configuration showing SubDevices appended to the CU2508 downlink port for Multiplier Real-time Ethernet Driver setup](../Media/CU2508_Configuration.PNG)